§2395.79. Equipment Bonding Jumpers. - California …

    https://www.dir.ca.gov/Title8/2395_79.html
    none

Equipment Grounding Conductor on the outside of a raceway?

    https://forums.mikeholt.com/threads/equipment-grounding-conductor-on-the-outside-of-a-raceway.89620/
    The NEC limits the bonding jumper to 6ft (with and exception for a pole top bond). 300.3 (B) requires all conductors to be grouped together - the further apart the circuit conductors are, the greater the impedance as the magnetic fields don't cancel. The NEC doesn't tell you the why, only the how. For the why, read the IEEE green book.

Outside Raceway or Enclosure | UpCodes

    https://up.codes/s/outside-raceway-or-enclosure
    Where installed outside of a raceway or enclosure, the length of the bonding jumper or conductor or equipment bonding jumper shall not exceed 6 feet (1829 mm) and shall be routed with the raceway or enclosure. [250.102 (E) (2)]

Equipment Bonding Jumper - Mike Holt's Forum

    https://forums.mikeholt.com/threads/equipment-bonding-jumper.65838/
    Equipment bonding jumpers are used to connect the grounding terminal of a receptacle to a metal box that in turn is grounded via an equipment grounding conductor in the form of a metal raceway system. Equipment bonding jumpers around expansion fittings for rigid metal conduit as required by 250.98 are shown in Exhibit 100.4 (below).

Bonding Conductors and Jumpers | UpCodes

    https://up.codes/s/bonding-conductors-and-jumpers
    Bonding jumpers or conductors and equipment bonding jumpers shall be permitted to be installed inside or outside of a raceway or an enclosure. (1) Inside a Raceway or an Enclosure If installed inside a raceway, equipment bonding jumpers and bonding jumpers or conductors shall comply with the requirements of 250.119 and 250.148.

Grounding level 1 Flashcards - Quizlet

    https://quizlet.com/493056235/grounding-level-1-flash-cards/
    Where loosely jointed metal raceways are used and, especially where there are expansion joints or telescoping sections of raceways, the National Electrical Code requires that they be made electrically continuous by the use of a (n) ? or other means. eqipment bonding jumper

ch 7 Flashcards by Brian Jones | Brainscape

    https://www.brainscape.com/flashcards/ch-7-8707190/packs/14738133
    An equipment bonding jumper is permitted to be installed either inside or outside of a raceway or enclosure. true 32 When an equipment bonding jumper is installed on the outside of flexible metal conduit or liquidtight flexible metal conduit, the length of the jumper is generally limited to not exceeding ? ...

Grounding and Bonding — Part 1 of 3 - EC&M

    https://www.ecmweb.com/national-electrical-code/code-basics/article/20897016/grounding-and-bonding-part-1-of-3
    If you use a single equipment bonding jumper to bond two or more raceways, size it per 250.122, based on the rating of the largest circuit overcurrent device. You can install equipment bonding jumpers, bonding jumpers, or bonding conductors inside or outside of a raceway. If inside a raceway, these conductors must be identified per 250.119.

Grounding & Bonding Lvl 1; Lesson 7 Flashcards

    https://www.chegg.com/flashcards/grounding-bonding-lvl-1-lesson-7-525f5882-997b-4210-b738-14a8f9a8e9f4/deck
    An equipment bonding jumper is permitted to be installed either inside or outside of a raceway or enclosure. True When an equipment bonding jumper is installed on the outside of flexible metal conduit or liquidtight flexible metal conduit, the length of the jumper is generally limited to no more than ... in length. 6'

Article 250 Grounding and Bonding (continued)

    http://garyklinka.com/necquiz102.htm
    The equipment bonding jumper can be installed on the outside of a raceway providing the length of the run is not more than ____ and the bonding jumper is routed with the raceway. a) 12 in. b) 24 in. c) 36 in. d) 72 in. 250.102 (E) 16. The metal water-piping system (s) must be bonded to the ____. a) grounded conductor at the service