§2395.79. Equipment Bonding Jumpers. - California Department o…

    https://www.dir.ca.gov/Title8/2395_79.html#:~:text=The%20equipment%20bonding%20jumper%20shall%20be%20permitted%20to,Part%203%2C%20Section%20250-79%20%28a%29%2C%20%28b%29%20and%20%28e%29.%29
    none

§2395.79. Equipment Bonding Jumpers. - California …

    https://www.dir.ca.gov/Title8/2395_79.html
    Equipment bonding jumpers shall be attached in the manner specified by the applicable provisions of Section 2395.113 for circuits and equipment. (c) Installation. The equipment bonding jumper shall be permitted to be installed inside or outside of a raceway or enclosure. Where installed on the outside, the length of the equipment bonding jumper shall not exceed …

Equipment Grounding Conductor on the outside of a raceway?

    https://forums.mikeholt.com/threads/equipment-grounding-conductor-on-the-outside-of-a-raceway.89620/
    bonding jumpers outside the conduit are limited to 6ft 250.102 (E) tom baker First Chief Moderator Staff member Location Bremerton, Washington Aug 31, 2011 #8 petersonra said: After thinking about it, I am not sure this is a violation. There is an EGC run with the conductors (the conduit). The wire on the outside of the conduit is a seperate issue.

Outside Raceway or Enclosure | UpCodes

    https://up.codes/s/outside-raceway-or-enclosure
    Where installed outside of a raceway or enclosure, the length of the bonding jumper or conductor or equipment bonding jumper shall not exceed 6 feet (1829 mm) and shall be routed with the raceway or enclosure. [250.102 (E) (2)] Equipment bonding jumpers and supply-side bonding jumpers installed for bonding grounding electrodes and installed at outdoor pole locations for …

Grounding and Bonding — Part 1 of 3 - EC&M

    https://www.ecmweb.com/national-electrical-code/code-basics/article/20897016/grounding-and-bonding-part-1-of-3
    If you use a single equipment bonding jumper to bond two or more raceways, size it per 250.122, based on the rating of the largest circuit overcurrent device. You can install equipment bonding jumpers, bonding jumpers, or bonding conductors inside or outside of a raceway. If inside a raceway, these conductors must be identified per 250.119.