Metal Stud Bracing Details | Iron Engineering

    https://iron-eng.com/cold-formed-steel-services/metal-stud-bracing-details/
    none

How to Brace Steel Stud Walls - Studco Systems US

    https://studcosystems.com/news-and-tech-tips/how-to-brace-steel-stud-walls/
    The Studco® M104 connector is designed for use in wall bracing applications and it boasts a large variety of holes sizes and locations to ensure that the bracing stud intersects with a minimum of four location holes on the connector bracket at all times. This also enables installation of bracing studs between 15° and 60° from the vertical plane.

Can metal studs be used horizontally?

    https://findanyanswer.com/can-metal-studs-be-used-horizontally
    A horizontal piece at the bottom of the wall is called the bottom plate. Also, can metal studs support weight? The axial load, or load weight limit, for metal studs varies widely. An 8-foot, 3-1/2-inch metal stud, for instance, may support over 2,000 pounds, while a 16-foot stud of the same width will support as little as 400 pounds.

Stud Bracing | UpCodes

    https://up.codes/s/stud-bracing
    Horizontal steel straps shall be not less than 1 1 / 2 inches in width and 33 mils in thickness (38 mm by 0.84 mm). Straps shall be attached to the flanges of studs with one No. 8 screw. In-line blocking shall be installed between studs at the termination of straps and at 12-foot (3658 mm) intervals along the strap.

Flat Strapping | ClarkDietrich Building Systems

    https://www.clarkdietrich.com/products/flat-strapping
    Horizontal strap lateral bracing for wall studs Commonly used bracing for wall studs deeper than 6" Properly spaced horizontal steel bracing provides resistance to stud rotation and minor axis buckling under wind and axial loads. Block and strapping is …

Stud wall bracing - Structural engineering general ...

    https://www.eng-tips.com/viewthread.cfm?qid=431199
    There is no ceiling, the stud walls are partitions and open above to the 24’ plus roof height. Stud walls usually have diagonal bracing at the top to keep them supported laterally and this is usually concealed by a drop ceiling. The client doesn’t want to see diagonal bracing all over the place going up to 24’ or 30’ high in some places.

TECHNICAL DESIGN CATALOG - Metal Stud Framing

    https://www.steeler.com/uploads/pdf/steeler-tech-cat_rs.pdf
    Also used for laterally bracing in steel stud wall systems and ornamental lathing. Available in galvanized per ASTM A-653 or equal. Materials a) Light gauge steel meeting the physical and galvanization requirements of ASTM A-653 or equal. b) Shape and Dimensions shown at left. c) Length - 10’-0” and 20”-0”. Special lengths are available.

Proper installation of metal strapping as shear bracing ...

    https://www.greenbuildingadvisor.com/question/proper-installation-of-metal-strapping-as-shear-bracing
    T-profile strapping and L-profile strapping are designed to be installed by inserting one leg of the strapping into a 1/2-in.-deep kerf cut into the studs and plates, and then nailing the strapping to each stud and plate. T-profile and L-profile strapping have an important advantage over flat strapping: They work in both compression and tension.

SSMA Framing Details - SCAFCO Steel Stud Company

    https://www.scafco.com/wp-content/uploads/SSMA_Detail_Drawings.pdf
    Use of cripple stud to receive head/sill tracks at the jamb studs helps maintain alignment of finishes. Back to back header reduces web-crippling reinforcement requirements. Boxed jamb studs welded together reduces material build-up and finish problems. 1. 2. 3. ADVANTAGES: Window - Load Bearing Back to Back Header Boxed Jamb. Page 6

U-Channel (CRC) | ClarkDietrich Building Systems

    https://www.clarkdietrich.com/products/u-channel-crc
    Lateral bracing is typically installed at a maximum of 48" O.C. Consult ClarkDietrich’s Technical Services for proper spacing. Welding U-Channel to the stud is acceptable but should not be used in studs wider than 6". Caution: Clip Angles must be used with screws to brace cold-formed framing properly.