    MII-GE90-D-SP 90 (basic) / 115 (ultimate) mph wind speed, exposure D. MII-REP19 Standard repair detail to notch 2×6 top chord of gable truss. MII-REP19A Standard repair detail to notch 2×4 top chord of gable truss. Alternate diagonal bracing to the bottom chord. Bracing requirements for structural gable trusses.

GABLE END BRACING

    https://miteknz.co.nz/wp-content/uploads/2021/06/Gable-End-Bracing.pdf
    flange at each gable brace connection to strongback able end truss 90x45 gable brace tandard truss spacing 90x45 runner over bottom chords of trusses. un over minimum 3 trusses. ix strongback gable brace and runner as below tud wall as per 36042011 ull height brick veneer - Max. height 5.5m on gable end wall lause 1.1.2o 36042011 trongback as ...

MiTeK Gable End and Bracing | PDF | Truss | Roof - Scribd

    https://www.scribd.com/document/382128709/MiTeK-Gable-End-and-Bracing
    MiTeK Gable End and Bracing Download now of 4 09/2011 GABLE END BRACING OVER ROOF SECTION OF END WALLS Covers bracing of the roof section on gable end construction. Includes bracing on extra high gables. All timber to be …

Bracing Details - MiTek Residential Construction Industry

    https://www.mitek-us.com/resources/engineering/bracing-details/
    Bracing Details - PDF Library

APRIL 12, 2019 Standard Gable End Detail MII-SHEET 2

    https://www.mitek-us.com/wp-content/uploads/uploadedFiles/_RedesignSite/Content/documents/engineering/details/gable-end-details/ENG-GABLE-st-ge-sheet2.pdf
    Standard Gable End DetailMII-SHEET 2 Trusses @ 24" o.c. Roof Sheathing 1'-3" Max. 2x6 DIAGONAL BRACE SPACED 48" O.C. ATTACHED TO VERTICAL WITH (4) -16d (0.131" X 3.5") NAILS AND ATTACHED TO BLOCKING WITH (5) - 10d (0.131" X 3") NAILS. PROVIDE 2x4 BLOCKING BETWEEN THE TRUSSES SUPPORTING THE BRACE AND THE TWO TRUSSES ON …

to Section B-B - MiTek Residential Construction Industry

    https://www.mitek-us.com/wp-content/uploads/uploadedFiles/_RedesignSite/Content/documents/engineering/details/gable-end-details/MII-GE100-001.pdf
    CONSTRUCT HORIZONTAL BRACE CONNECTING A 2x6 STUD AND A 2x4 STUD AS SHOWN WITH 16d NAILS SPACED 6" O.C. HORIZONTAL BRACE TO BE LOCATED AT THE MIDSPAN OF THE LONGEST STUD. ATTACH TO VERTICAL STUDS WITH (4) 10d NAILS THROUGH 2x4. (REFER TO SECTION A-A) GABLE STUD DEFLECTION MEETS OR EXCEEDS L/240.

Engineering Details - MiTek Residential Construction Industry

    https://www.mitek-us.com/resources/engineering/Engineering-Details/
    Some of these standard details may be sealed upon request. Contact MiTek Engineering Support for any questions. Roof Truss Repair Details. Floor …

Literature - MiTek New Zealand

    https://miteknz.co.nz/services/literature/
    MiTek Gable End Bracing. View PDF. MiTek Gable End Raking Verge. View PDF. Hip Board Prop. View PDF. MiTek Internal Load Bearing on Concrete Floor Slabs. View PDF. Jack Stud to Top Plate & Lintel Fixing. View PDF. Lintel Fixing Schedule. View PDF. New Zealand Exposure Map. View PDF. Purlin & Batten Fixing Chart.

GUIDE ROOF TRUSS Installation - mitek.com.au

    https://www.mitek.com.au/wp-content/uploads/2021/08/MGB0618-MiTek-Guide-for-Roof-Truss-Installation_WEB_FA-2021.pdf
    Gable Ends Where a gable end is required, consult your truss fabricator for details of construction and erection. Supporting Structure (Frame or Brick) A structure that is not level and is out of square will result in an ugly and unsatisfactory roof line. Time is well spent in ensuring: 1. The load bearing top plates are level. 2.

Scissor Trusses & Flat Bottomed Gable Ends - Rigidply Rafters

    https://www.rigidply.com/wp-content/uploads/pdf/Mitek-Article-on-Scissor-Trusses-and-Flat-Bottomed-Gable-Ends.pdf
    One method is to design a balloon-framed end wall, which will completely eliminate any need for a gable end frame. Another method is to use a gable end frame, but to make it match the profile of the adjacent scissor trusses so that the bracing can be installed correctly.