UDC Wall Bracing Provisions

    https://dsps.wi.gov/Documents/Programs/UDC/WallBracingGuide.pdf
    none

Frequently Asked Questions/UDC Wall Bracing …

    https://dsps.wi.gov/Documents/Programs/UDC/WallBracingFAQs.pdf
    STATE OF WISCONSIN Mail to: Department of Safety and Professional Services . PO Box 8935. 1400 E Washington Ave. Madison WI 53708-8935 . Madison WI 53703 . ... I am very comfortable using and complying with the Emergency Rule UDC Wall Bracing provisions. May I continue to use this method after the effective date of the Permanent Rules?

Wall Bracing Compliance Checklist/Worksheet

    https://dsps.wi.gov/Documents/Programs/UDC/WallBracingComplianceWorksheet.pdf
    Sketch and dimension the building plan and the wall bracing rectangle(s) per 321.25(8)(c)1. and Figure 321.25-B. Provide and label additional sketches if the building plan/rectangles change at different floor levels. Indicate applicable Wall Bracing Method for each level (see Table 321.25-G), each labeled rectangle if more than

DSPS One- & Two-Family (Uniform Dwelling Code)

    https://dsps.wi.gov/pages/Programs/UDC/Default.aspx
    The Uniform Dwelling Code (UDC) is the statewide building code for one- and two-family dwellings built since June 1, 1980. The Industry Services Division provides consultation and education concerning UDC construction standards and inspection procedures. Building materials are evaluated for conformance with standards.

Updated Wall Bracing Rules - Wisconsin Department of …

    https://www.youtube.com/watch?v=MHaPb1ieAHo
    More information may be found here:http://www.dsps.wi.gov/Programs/Industry-Services/Industry-Services-Programs/One-and-Two-Family-UDCYou may also reach us v...

UDC Wall Bracing Worksheet - Mount Horeb, Wisconsin

    https://www.mounthorebwi.info/wp-content/uploads/2014/04/UDC-Wall-Bracing-Worksheet.pdf
    Wall Bracing Compliance Worksheet Complete this worksheet or provide equivalent information on the plans submitted with the permit application. Sketch and dimension the building plan and the wall bracing rectangle(s) per and Figure 321.25-B. Provide and label additional sketches ifthe building plan/rectangles change at different floor levels.

Wisconsin Legislature: SPS 321.25 Text

    https://docs.legis.wisconsin.gov/code/admin_code/sps/safety_and_buildings_and_environment/320_325/321/VII/25/8/c/7/_19?up=1
    e Braced wall panels located on a common wall where angled rectangles intersect, as shown in Figure 321.25-B(3), shall have their contributing length applied towards the required length of bracing for the parallel rectangle side and its projected contributing lengths towards the adjacent angled rectangle sides. Where the common side of rectangle 2 as shown in Figure 321.25-B(3) …

UDC FAQs - Wisconsin

    https://dsps.wi.gov/Documents/Programs/UDC/FAQSPS321.pdf
    Wisconsin Department of Safety and Professional Services Division of Industry Services 4822 Madison Yards Way PO Box 7302 Madison WI 53707-7302 UDC FAQs Wind Loads using ASCE 7 SPS 321.02(1)(c) When designing wall bracing to comply with SPS 321.25(8), may I use the ASCE 7 standard as an option to determine

Wisconsin Legislature: SPS 321.25(6)(c)1.

    https://docs.legis.wisconsin.gov/document/administrativecode/SPS%20321.25(6)(c)1.
    b The actual measured wall height shall include stud height and thickness of top and bottom plates. The actual wall height shall be permitted to exceed the listed nominal values by not more than 4 ½ inches. Tabulated bracing amounts in s. SPS 321.25 (8) (c) are based on a 10-foot nominal wall height for all bracing methods and shall be permitted to be adjusted to other …

Chapter SPS 321 - docs.legis.wisconsin.gov

    https://docs.legis.wisconsin.gov/code/admin_code/sps/safety_and_buildings_and_environment/320_325/321.pdf
    Wall Framing Sole plate to joist or blocking, face nail 2−16d at 16 o.c. Top or sole plate to stud, end nail 2−16d Stud to sole plate, toe nail 3−8d or 2–16d Doubled studs, face nail 10d at 24 o.c. Doubled top plates, face nail 10d at 24 o.c. Doubled top plates, minimum 24−inch offset of end joints, face nail in lapped area 8–16d